1.
Braz. dent. j ; 35: e24, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1550092

ABSTRACT

Abstract This study verified the effect of the combination of preheated hydrofluoric acid/silane/electric current in the adhesion of the resin cement to ceramic. IPS E.max Press ceramic discs embedded in PVC rigid tubes were divided into four groups associating preheated hydrofluoric acid and silane applied with electrical current (n=10): Ha+S (Heated acid + silane); Ha+S+Ec (Heated acid + silane + electrical current); A+S (Acid + silane) and A+S+Ec (Acid + silano + electrical current). Resin cement/ceramic samples were stored in water at 37°C for 24h. After storage, they were submitted to the microshear test, fracture analysis, and contact angle at 24h or after thermocycling (10,000 cycles/5-55ºC). Bond strength data were evaluated by two-way ANOVA. For comparison between evaluation times (24h or thermocycling) was applied unpaired t-test. A significance post-hoc test of p=0.05 was assumed for analyses and graphs (GraphPad Prism 9.0 software). At 24h, the microshear strength showed similar values between Ha+S, Ha+S+Ec, and A+S+Ec groups, while A+S showed the lowest value with a statistical difference. After thermocycling, Ha+S and Ha+S+Ec were similar, as well as A+S and A+S+Ec. There was a significant difference in all groups comparing 24h (highest value) with after thermocycling (lowest value). Adhesive fracture was predominant in all groups and evaluation times. Ha+S and A+S groups showed higher contact angle values compared to the Ha+S+Ec and A+S+Ec with lower values. In conclusion, the association of preheated hydrofluoric acid/silane applied or not with electric current promoted different microshear strength values, fracture types, and contact angles in the resin cement/ceramic bond.


Resumo Este estudo verificou o efeito da combinação ácido fluorídrico pré-aquecido/silano/corrente elétrica na adesão do cimento resinoso à cerâmica. Os discos cerâmicos IPS E.max Press embutidos em tubos rígidos de PVC foram separados em quatro grupos associando ácido fluorídrico pré-aquecido e silano aplicado com corrente elétrica (n=10): Ha+S (ácido aquecido + silano); Ha+S+Ec (Ácido aquecido + silano + corrente elétrica); A+S (Ácido + silano) e A+S+EC (Ácido + silano + corrente elétrica). Amostras de cimento resinoso/cerâmica foram armazenadas em água a 37°C por 24 horas. Após o armazenamento foram submetidas ao ensaio de micro cisalhamento, análise de fratura e ângulo de contato no período de 24 horas ou após termociclagem (10.000 ciclos/5-55ºC). Os dados de resistência de união foram avaliados por ANOVA dois fatores. Para comparação entre os tempos de avaliação (24 horas ou termociclagem) foi aplicado o teste t não pareado. Foi assumida significância de 5% para análises e gráficos (software GraphPad Prism 9.0). Em 24 horas, a resistência ao micro cisalhamento apresentou valores similares entre os grupos Ha+S, Ha+S+Ec e A+S+Ec, enquanto A+S apresentou menor valor com diferença estatística. Após a termociclagem, Ha+S e Ha+S+Ec foram similares, assim como A+S e A+S+Ec. Houve diferença significativa em todos os grupos comparando 24 horas (maior valor) com após termociclagem (menor valor). A fratura adesiva foi predominante em todos os grupos e tempos de avaliação. Os grupos Ha+S e A+S apresentaram maiores valores de ângulos de contato comparados aos grupos Ha+S+Ec e A+S+Ec com valores menores. Em conclusão, a associação ácido fluorídrico pré-aquecido/silano aplicado com corrente elétrica promoveu diferentes valores de resistência ao micro cisalhamento, tipos de fratura e ângulos de contato na adesão do cimento resinoso à cerâmica.

2.
Braz. dent. j ; 35: e24, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1550094

ABSTRACT

Abstract This study investigated microshear bond strength (µSBS) of two (2) dual-cured resin-luting agents (RelyX™ Ultimate and RelyX™ U200) when photoactivated through varying thicknesses of lithium disilicate, with or without thermal cycling. Discs of IPS e.max Press of 0.5, 1.5, and 2 mm in thickness were obtained. Elastomer molds (3.0 mm in thickness) with four cylinder-shaped orifices 1.0 mm in diameter, were placed onto the ceramic surfaces and filled with resin-luting agents. A Mylar strip, glass plate, and load of 250 grams were placed over the filled mold. The load was removed and the resin-luting agents were photoactivated through the ceramics using a single-peak LED (Radii Plus.) All samples were stored in distilled water at 37oC for 24 h. Half of the samples were subjected to thermal cycling (3,000 cycles; 5ºC and 55ºC). All samples were then submitted to µSBS test using a universal testing machine (Instron 4411) at a crosshead speed of 0.5 mm/min. Data were submitted to three-way ANOVA and Tukey post-hoc test (α=0.05). The mean µSBS at 24 h was significantly higher than after thermal cycling (p<0.05). No statistical difference was found between resin-luting agents (p > 0.05). The mean µSBS for groups photoactivated through 0.5 mm ceramic were significantly higher than 1.5 mm and 2.0 mm (p < 0.05). In conclusion, increased ceramic thicknesses reduced the bond strength of tested resin-luting agents to lithium disilicate. No differences were found between resin-luting agents. Thermal cycling reduced the bond strength of both resin-luting agents.


Resumo: Este estudo investigou a resistência de união ao microcisalhamento (RUµC) de dois (2) agentes de cimentação de resina dual (RelyX™ Ultimate e RelyX™ U200) quando fotoativados através de diferentes espessuras de dissilicato de lítio, com ou sem ciclagem térmica. Discos do IPS e.max Press de 0,5, 1,5 e 2 mm de espessura foram obtidos. Moldes de elastômero (3,0 mm de espessura) com quatro orifícios cilíndricos de 1,0 mm de diâmetro foram colocados sobre as superfícies cerâmicas e preenchidos com agentes de cimentação de resina. Uma tira Mylar, placa de vidro e carga de 250 gramas foram colocadas sobre o molde preenchido. A carga foi removida e os agentes de cimentação resinosos foram fotoativados através da cerâmica usando um LED de pico-único (Radii Plus). Todas as amostras foram armazenadas em água deionizada a 37oC por 24 h. Metade das amostras foi submetida a ciclagem térmica (3.000 ciclos; 5ºC e 55ºC). Todas as amostras foram então submetidas ao teste de RUµC usando uma máquina de teste universal (Instron 4411) com velocidade de 0,5 mm/min. Os dados foram submetidos à Análise de Variância três fatores e ao teste post-hoc de Tukey (α = 0,05). A média de RUµC em 24 h foi significativamente maior do que após a ciclagem térmica (p < 0,05). Não houve diferença estatística entre os cimentos resinosos (p > 0,05). As médias de RUµC para grupos fotoativados através de cerâmica de 0,5 mm foram significativamente maiores do que 1,5 mm e 2,0 mm (p < 0,05). Em conclusão, o aumento da espessura da cerâmica reduziu a resistência de união dos agentes de cimentação resinosos ao dissilicato de lítio. Não foram encontradas diferenças entre os agentes de cimentação resinosos. A ciclagem térmica reduziu a resistência de união de ambos os agentes de cimentação resinosos.

3.
Braz. dent. j ; 35: e24, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1550097

ABSTRACT

Abstract This study verified the effect of surface treatments of the zirconia-reinforced lithium disilicate ceramic bonded to resin cement. Ceramic blocks were divided according to treatments (n=10): FA+SRX (Fluoric acid + silane RX), FA+MDP (Fluoric acid + MDP), FA+SCF+MDP (Fluoric acid + silane CF + MDP), FA+MEP (Fluoric acid + MEP), and MEP (Self-etch primer). Resin cement cylinders were made in the ceramic blocks, photoactivated with 1,200 mW/cm² for 40s, stored in water at 37°C for 24h, and evaluated by the microshear strength test, optical failure descriptive analysis (%), surface characterization (SEM) and contact angle (Goniometer). Other samples were submitted to 10,000 thermocycles between 5°C and 55°C. Bond strength data were submitted to two-way ANOVA and Tukey's test. Contact angle to one-way ANOVA and Games-Howell's test (5%). At 24h, MEP showed higher bond strength, and FA+SRX the lower. FA+MDP and FA+SCF+MDP showed similar values and FA+MEP was intermediate. After thermocycling, FA+SCF+MDP, FA+MEP, and MEP showed higher values, and FA+SRX the lower while FA+MDP was intermediate. When the periods were compared, FA+MDP, FA+SCF+MDP, FA+MEP, and MEP showed higher values for 24h while FA+SRX was similar. SEM showed retentive surface and crystal exposure when treated with FA+SCF+MDP. The less retentive surface was obtained with MEP, and the other treatments promoted intermediate irregularities. In conclusion, surface treatment and thermocycling promoted different values of adhesive strength and contact angle in a zirconia-reinforced lithium silicate ceramic. Failures were predominantly adhesive, and the ceramic surface was characterized by different levels of roughness and selective exposure of crystals.


Resumo O objetivo neste estudo foi verificar o efeito de tratamentos de superfície da cerâmica de dissilicato de lítio reforçada com zircônia fixada ao cimento resinoso. Os blocos cerâmicos foram separados de acordo com os tratamentos (n=10): AF+SRX (ácido fluorídrico + silano), AF+MDP (ácido fluorídrico + MDP), AF+SCF+MDP (ácido fluorídrico + silano + MDP), AF+MEP (Ácido fluorídrico + MEP) e MEP (Primer auto condicionante). Cilindros de cimento resinoso foram confeccionados em cada bloco cerâmico, foto ativados com 1.200 mW/cm² por 40 segundos, armazenados em água a 37°C por 24 horas e avaliados pelo teste de resistência ao micro cisalhamento, falha por análise descritiva em microscopia óptica (%), caracterização da superfície por imagens MEV e ângulo de contato (Goniômetro). Outras amostras foram submetidas a 10.000 ciclos térmicos (5° e 55°C). Os dados de resistência de união foram submetidos a ANOVA dois fatores e teste de Tukey (5%). Ângulo de contato com ANOVA um fator e teste de Games-Howell (5%). Em 24 horas, MEP apresentou maior resistência de união e AF+S a menor. AF+MDP e AF+SCF+MDP apresentaram valores similares e AF+MEP foi intermediário. Após a ciclagem térmica, AF+SCF+MDP, AF+MEP e MEP apresentaram valores maiores e AF+SRX o menor enquanto AF+MDP foi intermediário. Quando comparados os períodos, AF+MDP, AF+SCF+MDP, AF+MEP e MEP apresentaram valores maiores em 24 horas enquanto AF+SRX foi similar. MEV mostrou superfície mais retentiva e exposição de cristais quando tratada com AF+SCF+MDP. A superfície menos retentiva foi obtida com MEP, e os demais tratamentos promoveram irregularidades de superfície intermediárias. Conclui-se que o tratamento superficial e a termociclagem promoveram diferentes valores de resistência adesiva e ângulo de contato em cerâmica de silicato de lítio reforçada com zircônia. As falhas foram predominantemente adesivas, e a superfície cerâmica foi caracterizada com diferentes níveis de rugosidade e exposição seletiva de cristais.

4.
Braz. oral res. (Online) ; 37: e065, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1439737

ABSTRACT

Abstract The aim of this study was to quantify the force exerted by tandem archwires in a specific system of passive self-ligating bracket. Forty-eight thermo-activated nickel-titanium orthodontic archwires were separated into four groups (n = 12): G1 - two .014" + .014" round archwires; G2 - two .014" + .016" round archwires; G3 - .014" x .025" rectangular archwire; and. G4 - .016" x .022" rectangular archwire. Brackets were fixed onto teeth 1.5 to 2.5 using a device that represented the upper teeth, maintaining an interbracket distance of 6.0 mm. The deflection tests were performed using the structure representative of tooth 1.1 as support on the Instron testing machine at a speed of 2.0 mm/min. The archwires were evaluated at deflections of 0.5 mm, 1.0 mm, and 1.5 mm. The data were analyzed by a generalized linear model, considering values at different deflections as repeated measurements in the same experimental unit (α = 0.5%). At 0.5 mm, higher forces were observed in G2 and G3, which did not differ significantly (p > 0.05). The lowest force was observed in G4 (p < 0.05). At 1.0 mm and 1.5 mm, the highest force was observed in G3, followed by G4 and G2 (p < 0.05). The lowest force was observed in G1 (p < 0.05). In general, tandem archwires (same or different calibers) in a specific passive self-ligating bracket exerted lower force when compared with rectangular archwires.

5.
Braz. dent. j ; 33(5): 55-63, Sep.-Oct. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1403787

ABSTRACT

Abstract A new device was developed to enable the visualization and measurement of canine angulation while at the same time visualizing and measuring the force transmitted to adjacent teeth. This study aimed to evaluate the mesiodistal tilt angle of the upper canine brackets, the wire deflection, and its effects on adjacent teeth with five different slot designs of upper canines. Wires (0.020" and 0.019" x 0.025") were tested on different five bracket types at five different distal angles. The force applied to adjacent teeth was measured as the angle was increased, and its consequences were observed in the posterior and anterior regions as well. The force tension (gf) was measured in a universal testing machine. Data were submitted to a 3-way ANOVA and Tukey's test (α=0.05). For both arches, regardless of the type of tooth and bracket type, the highest means tension mean values were shown by the 20° angle, followed by the 15°,10°, and 5° angles, which differed statistically among themselves. Overall, for 5°, 10°, and 15° angles, conventional and versatile brackets showed significantly higher force values in all teeth, tip-edge and control brackets showed the lowest. The highest force values were observed in central and lateral incisors with conventional and versatile brackets and on first and second premolar teeth with self-ligating passive and control brackets. Conventional brackets presented the highest forces, tip-edge and control brackets showed the lowest. The teeth that suffered the greatest forces were lateral incisors, and those that suffered the least were second premolars.


Resumo Foi desenvolvido um novo dispositivo para permitir a visualização e medição da angulação canina ao mesmo tempo que se visualiza e mede a força transmitida aos dentes adjacentes. Este estudo avaliou o ângulo de inclinação mesiodistal dos braquetes caninos superiores, a deflexão do fio, e os seus efeitos nos dentes adjacentes com cinco diferentes desenhos de ranhuras dos caninos superiores. Os fios (0,020" e 0,019" x 0,025") foram testados em cinco diferentes tipos de braquetes e ângulos distais. A força aplicada aos dentes adjacentes foi medida a medida que o ângulo era aumentado, e as suas consequências foram observadas também nas regiões posterior e anterior. A tensão da força (gf) foi medida em uma máquina de ensaio universal (Instron). Os dados foram submetidos ao teste ANOVA 3 fatores e Tukey (α=0,05). Para ambos os arcos, independentemente do tipo de dente e tipo de braquete, os valores médios de tensão mais elevados foram mostrados pelo ângulo de 20°, seguido pelos ângulos de 15°, 10°, e 5°, que diferiram estatisticamente entre si. Em geral, para ângulos de 5°, 10° e 15°, os braquetes convencionais e versáteis apresentaram valores de força significativamente mais elevados em todos os dentes, braquetes tip-edge e controle apresentaram os mais baixos. Os maiores valores de força foram observados nos incisivos centrais e laterais com braquetes convencionais e versáteis e no primeiro e segundo pré-molares com braquetes auto-ligantes passivo e controle. Os braquetes convencionais apresentaram as forças mais elevadas, os braquetes controle e tip-edge apresentaram os valores mais baixos. Os dentes que sofreram as maiores forças foram os incisivos laterais, e os que sofreram menos foram os segundos pré-molares.

6.
Braz. oral res. (Online) ; 36: e075, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384195

ABSTRACT

Abstract This study aimed to evaluate the effect of light attenuation through ceramic veneers and resin cement on degree of conversion (DC), cohesive strength (CS), and microshear bond strength (μSBS) of experimental adhesive systems. Experimental etch-and-rinse and self-etch adhesives were combined with different ratios of camphorquinone (CQ) and diphenyl(2,4,6-trimethylbenzoyl) phosphine oxide (TPO) photoinitiators: CQ-only; 3CQ:1TPO; 1CQ:1TPO; 1CQ:3TPO and TPO-only. Square-shaped ceramic veneer (IPS Empress Esthetic, Ivoclar Vivadent) (n = 10; 10mm long x 10mm wide x 0.5mm thick) and resin cement specimens (Variolink Esthetic LC, Ivoclar Vivadent) (n = 10; 10 mm long x 10 mm wide and 0.3 mm thick) were prepared. Light transmittance of a multiple-peak LED (Bluephase G2, Ivoclar Vivadent) was measured through restorative materials using a spectrometer (n = 5). Adhesive specimens were analyzed for DC, CS, and μSBS by light-curing the adhesive with or without (control) ceramic veneer, and with resin cement fixed to output region of the light-curing tip (n = 10). Data were submitted to ANOVA and Tukey's test (α = 0.05). Total light transmittance through the restorative materials was attenuated, and this attenuation was more evident for the violet spectrum. The DC for the TPO groups in ratios up to 1CQ:1TPO was similar to the control. 1CQ:3TPO showed lower values for CS. μSBS was reduced for all groups with light attenuation, but lower values were observed for 1CQ:3TPO and TPO-only. In conclusion, light transmission was reduced with interposed restorative materials. Adhesives combined with CQ and TPO up to 1CQ:1TPO showed greater cure efficiency and mechanical properties compared with a higher amount of TPO.

7.
Braz. dent. j ; 32(5): 77-86, Sept.-Oct. 2021. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1350295

ABSTRACT

Abstract This in vitro study aimed to evaluate the gaps length and depth of cure of dual-cure bulk-fill resin composites inserted in box-shaped preparations. Box-shaped preparations (4 mm deep) were made in fifteen human third-molars and divided into three groups according to the resin composites (n=5): Dual-cure bulk-fill BulkEZ (BEZ); Dual-cure bulk-fill HyperFIL (HF); and Tetric Evoceram Bulk-fill (TETRIC), as control. Gaps length (%) was evaluated in tooth-restoration interface with micro-computed tomography (µCT). The restorations were sectioned, and the degree of conversion (DC) and Knoop microhardness were evaluated at five depths (0.3, 1, 2, 3, and 4 mm). Microhardness data were statistically evaluated using absolute values (KHN) and relative values (microhardness percentages in relation to top). Gaps length (%) increased in the following order: BEZ=TETRIC<HF. The microhardness percentages in relation to top significantly decreased from 2 mm for TETRIC and 3 mm for HF. BEZ had constant microhardness and DC at all depths, while HF and TETRIC presented a significant decrease on DC at 4 mm. Dual-cure bulk-fill composites did not reduce gaps compared to light-cure bulk-fill, but they can improve depth of cure of bulk-filled restorations.


Resumo O objetivo neste estudo in vitro foi mensurar as fendas e a profundidade de polimerização de compósitos resinosos bulk-fill duais inseridos em preparos em forma de caixa. Os preparos em forma de caixa (4 mm de profundidade) foram realizados em quinze terceiros molares e separados em 3 grupos, de acordo com o compósito resinoso (n = 5): Bulk-fill dual BulkEZ (BEZ); Bulk-fill dual HyperFIL (HF); Tetric Evoceram Bulk-fill (TETRIC). O comprimento das fendas (%) foi avaliado na interface dente-restauração por meio de micro-tomografia computadorizada (µCT). As restaurações foram seccionadas e o grau de conversão (GC) e microdureza Knoop foram avaliados em cinco profundidades (0,3, 1, 2, 3 e 4 mm). Os dados de microdureza foram avaliados estatisticamente por meio de valores absolutos e relativos (porcentagens de microdureza em relação ao topo). O comprimento das fendas (%) aumentou na seguinte ordem: BEZ = TETRIC <HF. O percentual de microdureza em relação ao topo diminuiu significativamente a partir de 2 mm para TETRIC e 3 mm para HF. BEZ apresentou percentuais de microdureza e de GC constantes em todas as profundidades, enquanto HF e TETRIC apresentaram decréscimo significativo no GC em 4 mm. Os compósitos resinosos bulk-fill duais não reduziram as fendas formadas quando comparados a um compósito bulk-fill fotopolimerizável; entretanto, os mesmos podem melhorar a profundidade de polimerização em restaurações de incremento único.

8.
Braz. dent. j ; 32(4): 55-61, July-Aug. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1345512

ABSTRACT

Abstract The purpose of this in vitro study was to evaluate the force decrease of different elastomeric chains after different times: initial, 10 minutes, 1 day, 28 days and after mechanical brushing. Twenty orthodontic elastomeric chains segments were utilized for each commercial brand. Initially, the elastomeric chain of 15mm long were immediate stretched up to 20 mm in an Instron and the force was measured in gf. After all specimens were placed stretched on rectangular acrylic jigs with distance of 20 mm, immersed in deionized water at 37oC for 10 minutes and the force (gf) was measured again. Five test measurements of remaining force were made at the following time intervals: initial, 10 minutes, 1 day, 28 days and mechanical brushing. After 28 days, the acrylic plates with the specimens were adapted in the mechanical brushing machines (MSCT 3) and the elastomeric chains were submitted to mechanical brushing and the force (gf) measure again. The force (gf) was submitted to mixed-model ANOVA and Sidak post-hoc test (α=0.05). A statistically significant reduction in the force was found for all orthodontic elastomeric chain types after 1 day, 28 days and mechanical brushing (p<0.05). Morelli and 3M Unitek elastomeric chains showed significantly higher force than Abzil and GAC (p<0.05) after 1 day, 28 days and mechanical brushing. In conclusion, the force delivered by all elastomeric chains decayed rapidly over time. Morelli and 3M Unitek elastomeric chains consistently had a significantly greater force after mechanic brushing, while GAC the lowest.


Resumo O objetivo deste estudo in vitro foi avaliar a redução da força de diferentes cadeias elastoméricas após diferentes tempos: inicial, 10 minutos, 1 dia, 28 dias e após escovação mecânica. Vinte segmentos de cadeias elastoméricas ortodônticas foram utilizadas para cada marca comercial. Inicialmente, a cadeia elastomérica de 15 mm de comprimento foi esticada imediatamente até 20 mm na Instron e a força foi medida em (gf). Após, todas as amostras foram adaptadas esticadas em placas retangulares de acrílico na distância de 20 mm, imersas em água deionizada a 37o C por 10 minutos e a força (gf) foi medida novamente. Cinco medidas de força foram feitas nos seguintes intervalos de tempo: inicial, 10 minutos, 1 dia, 28 dias e após a escovação mecânica. Após 28 dias, as placas de acrílico com as amostras foram adaptadas na máquina de escovação (MSCT 3) e as cadeias elastoméricas foram submetidas a escovação mecânica e a medida de força (gf) novamente. Os dados da força (gf) foram submetidos a ANOVA modelo misto e teste post-hoc de Sidak (α = 0,05). Uma redução estatisticamente significativa na força foi encontrada para todos os tipos de cadeia elastomérica ortodôntica após 1 dia, 28 dias e escovação mecânica (p<0,05). As cadeias elastoméricas Morelli e 3M Unitek apresentaram força significativamente superior em relação a Abzil e GAC (p<0,05) após 1 dia, 28 dias e escovação mecânica. Em conclusão, a força distribuída por todas as cadeias elastoméricas decaiu rapidamente com o tempo. As cadeias elastoméricas Morelli e 3M Unitek consistentemente tiveram uma força significativamente maior após a escovação mecânica, enquanto GAC a mais baixa.


Subject(s)
Orthodontic Appliances , Elastomers , Stress, Mechanical , Toothbrushing , Materials Testing , Elasticity
9.
Braz. dent. j ; 32(4): 106-115, July-Aug. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1345518

ABSTRACT

Abstract The aim of this study was to evaluate the effect of 2% chlorhexidine digluconate (CHX) on microtensile bond strength (µTBS) between an adhesive system and under 3 dentin conditions. For that, this study evaluated the adhesive interface at initial, after 6 months and 1 year of storage. Forty-eight human third molars were prepared and randomly divided into 3 groups, according to dentin substrates: sound dentin (Sd), caries-infected dentin (Ci) and caries-affected dentin (Ca). The groups were subdivided into two according to the dentin pre-treatment: application of 2% CHX or without pre-treatment (control). The dentin surfaces were etched with 35% phosphoric acid gel and bonded with Adper Single Bond 2 (3M ESPE) adhesive system according to manufacturer's instructions. Subsequently, the specimens were stored in deionized water at 37°C for 24h, 6 months and 1 year. Two additional teeth were used to analyze the bonding interfaces by SEM. Data was submitted to three-way ANOVA in a split plot design and Tukey's test (α = 0.05). The results showed that Ci decreased µTBS values when compared to Ca and Sd, regardless storages time or treatment. Stored samples for 6 months and 1 year decreased the µTBS for the control group, but no difference was found between storages time for the CHX group. As a conclusion, the 2% CHX application after etching showed improved dentin bond strength in the storage time, regardless of the substrates evaluated.


Resumo O objetivo deste estudo foi avaliar o efeito do digluconato de clorexidina 2% (CHX) na resistência de união à microtração (µTBS) entre um sistema adesivo e sob 3 condições de dentina. Para tanto, este estudo avaliou a interface adesiva no início, após 6 meses e 1 ano de armazenamento. Quarenta e oito terceiros molares humanos foram preparados e divididos aleatoriamente em 3 grupos, de acordo com os substratos dentinários: dentina hígida (Dh), dentina infectada por cárie (Di) e dentina afetada por cárie (Da). Os grupos foram subdivididos em dois de acordo com o pré-tratamento: aplicação de CHX 2% ou sem pré-tratamento (controle). As superfícies da dentina foram condicionadas com gel de ácido fosfórico a 35%, em seguida, utilizou-se o sistema adesivo Adper Single Bond 2 (3M ESPE) de acordo com as instruções do fabricante. Posteriormente, os corpos-de-prova foram armazenados em água deionizada a 37°C por 24h, 6 meses e 1 ano. Dois dentes adicionais foram usados ​​para analisar as interfaces de união no MEV. Os dados foram submetidos a ANOVA três fatores em esquema de parcela subdividida e ao teste de Tukey (α = 0,05). Os resultados mostram que a Di diminuiu os valores de µTBS quando comparado as Da e Dh, independente do tempo de armazenamento ou tratamento. Amostras armazenadas por 6 meses e 1 ano diminuíram a µTBS para o grupo de controle, mas nenhuma diferença foi encontrada entre o tempo de armazenamento para o grupo CHX. A aplicação de CHX 2% após o condicionamento apresentou melhora na resistência de união à dentina no tempo de armazenamento, independente dos substratos avaliados.


Subject(s)
Humans , Dental Bonding , Dentin-Bonding Agents , Tensile Strength , Materials Testing , Composite Resins , Resin Cements , Dentin
10.
Rev. odontol. UNESP (Online) ; 49: e20200021, 2020. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1139429

ABSTRACT

Introduction: The sterilization and disinfection procedures should be adapted to the chemical profile of the metal alloys present in the instruments. Objective: This study aimed to perform a micrographic assessment on the surface characteristics of the widia of orthodontic pliers with two alloy compositions subjected to the action of 0.2% peracetic acid and intensive use. Material and method: Twenty distal cutting pliers were divided into two groups (n=10) according to widia composition (%wt): W1- 85% to 87% of tungsten carbide (TC) and other components in the proportion of 13% to 15% and W2 - 87.5% to 88.5% of tungsten carbide and 11.5% to 12.5% for other components. All the pliers were assessed in a stereoscopic magnifying glass (32x) after three treatments: before use (T0); after cutting 100 segments of rectangular stainless-steel wires - intensive use (T1); and after 100 sterilization cycles in 0.2% peracetic acid and intensive use (T2). The cutting sites of all pliers were standardized. Widia regions were defined by line "A" representing T1 and line "B" representing T2. A frequency distribution table and Fisher's exact test (α=0.05) was performed. We assessed two widia from each composition and treatment in SEM and energy-dispersive X-ray spectroscopy (EDS/SEM). Result: The results showed that W1 pliers presented significantly fewer defects after the sterilization cycles with peracetic acid and intensive use than W2 pliers (p=0.0198). There were no differences between both pliers after intensive use (p=1.000). Conclusion: The SEM images and EDS analyses showed changes in widia surfaces after the different treatments. Widia composition affected the resistance of the orthodontic pliers after sterilization cycles with 0.2% peracetic acid and intensive use.


Introdução: Os procedimentos de esterilização e desinfecção devem ser adaptados ao perfil químico das ligas metálicas presentes nos instrumentos. Objetivo: O objetivo do estudo foi realizar uma avaliação micrográfica das características da superfície da widia de alicates ortodônticos com duas composições de ligas submetidas à ação de ácido peracético a 0,2% e uso intensivo. Material e método: Vinte alicates de corte distal foram divididos em dois grupos (n=10), de acordo com a composição widia (% em peso): W1- 85% a 87% de carboneto de tungstênio e outros componentes na proporção de 13% a 15% e W2 - 87,5% a 88,5% de carboneto de tungstênio e 11,5% a 12,5% para outros componentes. Os alicates foram avaliados em uma lupa estereoscópica (32x) após três tratamentos: antes do uso (T0); após corte de 100 segmentos de fios retangulares de aço inoxidável- uso intensivo (T1); após 100 ciclos de esterilização em ácido peracético a 0,2% e uso intensivo (T2). Os locais de corte dos alicates foram definidos pela linha "A" representando T1 e pela linha "B" representando T2. Foi realizada uma tabela de distribuição de frequências e o teste exato de Fisher (α=0,05). As widias foram avaliadas em MEV e Espectroscopia de Energia Dispersiva. Resultado: Os alicates W1 apresentaram defeitos significativamente menores após os ciclos de esterilização com ácido peracético e uso intensivo do que os alicates W2 (p=0,0198). Não houve diferenças entre os dois alicates após uso intensivo (p=1.000). Conclusão: As imagens de MEV/EDS mostraram alterações nas superfícies widia após os diferentes tratamentos. A composição widia afetou a resistência do alicate ortodôntico após ciclos de esterilização com ácido peracético a 0,2% e uso intensivo.


Subject(s)
Orthodontics , Spectrum Analysis , Microscopy, Electron, Scanning , Sterilization , Disinfection , Dental Disinfectants , Dental Instruments
11.
Rev. odontol. UNESP (Online) ; 48: e20190022, 2019. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1020754

ABSTRACT

Abstract Introduction The orthodontic movement is directly influenced by the ability of orthodontic wires to slide through brackets and tubes. Therefore, the main concern during orthodontic movement corresponds to the frictional forces generated at the bracket-orthodontic wire interface. Objective This study aimed to evaluate the frictional resistance of esthetic orthodontic wires. Material and method Fifty test brackets were obtained and divided into five groups (n = 10) based on the type of rectangular orthodontic wire, as follows: conventional metallic wire (Morelli, Brazil) (G1, control group) and esthetic wires (G2, Ortho Organizer; G3, Tecnident; G4, Trianeiro; and G5, TP Orthodontics). The following materials and conditions were used: 0.019 x 0.025-inch wires, ceramic brackets with edgewise prescription, torque and/or angulation of 0°, and 0.022 x 0.028-inch slots. The specimens were tested for their tensile strength using an Instron universal test machine at a speed of 1.0 mm / min and a load cell of 500N. The tensile strength data were analyzed by one-way analysis of variance (ANOVA) followed by Tukey's post-hoc test, with a 5% significance level. Result The frictional resistance (N) of the metallic orthodontic wire (8.07 ± 0.43) was significantly higher than that of the esthetic wires: Ortho Organizer (4.01 ± 0.25), Tecnident (3.87 ± 0.31), Trianeiro (4.47 ± 0.26) and TP Orthodontics (4.49 ± 0.30) (p <0.05), with no significant difference between them (p> 0.05). Conclusion To conclude, the esthetic orthodontic wires tested herein showed less frictional resistance as compared to the conventional metallic wire.


Resumo Introdução O movimento ortodôntico bem sucedido está diretamente relacionado com a capacidade de os fios ortodônticos deslizarem sobre os bráquetes e tubos ortodônticos. Portanto, durante a movimentação ortodôntica a principal preocupação está diretamente ligada a fricção entre o suporte e o fio. Objetivo O objetivo deste estudo foi avaliar a influência de fios ortodônticos estéticos na resistência ao atrito. Material e método Foram utilizados 50 bráquetes-teste divididos em 5 grupos, de acordo com o fio retangular (n=10): G1 - grupo controle: fio metálico convencional (Morelli, Brasil) e fios estéticos (G2 - Ortho Organizer; G3 - Tecnident; G4 - Trianeiro; e, G5 - TP Orthodontics). Todos os fios apresentavam 0,019 x 0,025 polegadas e o bráquete era cerâmico, prescrição Edgewis e, torque e/ou angulação 0° e, canaleta 0,022 x 0,028 polegadas. O teste de resistência ao atrito sob força de tração foi realizado em uma máquina de ensaio universal Instron à velocidade de 1,0 mm/min e célula de carga de 500N. Os dados de resistência ao atrito foram submetidos à análise de variância (ANOVA) um fator e ao Teste de Tukey com nível de significância de 5%. Resultado O atrito (N) do fio metálico (8,07±0,43) foi significativamente maior que os fios ortodônticos estéticos: Ortho Organizer (4,01±0,25), Tecnident (3,871±0,31), Trident (4,47±0,26) e, TP (4,49±0,30) (p<0,05). Nenhuma diferença estatisticamente significativa foi observada entre os fios estéticos (p>0,05). Conclusão Conclui-se que os fios ortodônticos estéticos apresentam menor resistência ao atrito quando comparado ao fio metálico.


Subject(s)
Orthodontic Wires , Tensile Strength , Friction , Orthodontics , Orthodontic Brackets , Dental Porcelain
12.
J. appl. oral sci ; 27: e20180262, 2019. tab
Article in English | LILACS, BBO | ID: biblio-1019969

ABSTRACT

Abstract The incorporation of antimicrobials in the composites as an attempt to reduce bacterial adhesion without jeopardizing mechanical properties is a challenge for Dentistry. Objective: To evaluate the bacterial adhesion and physical properties of a composite containing the methacrylate triclosan- derivative monomer (TM). Methodology: TM was synthesized and added to an experimental composite. Samples were divided into two groups: Control and TM (13.4 wt%). Antibacterial Activity: Three specimens of each material were prepared and placed on bacterial suspensions of Streptococcus mutans for 1, 5 and 10 days. After these periods the counting of the colonies (log10) was performed. Assays was performed in triplicate. Physical Properties: Three-body Abrasion (TBA): Ten specimens of each material were prepared and stored at 37°C/24 h. The surface roughness (Ra) and hardness (KHN) were analyzed. Next, the specimens were submitted to abrasive wear (30,000 cycles) and re-evaluated for Ra and KHN; Sorption/solubility (SS): cylindrical specimens (n=10) were prepared and weighted. The specimens were immersed in deionized water for 7 days at 37°C and then their weight was verified again. SS were calculated using accepted formulas; Diametral tensile strength (DTS): specimens (n=10) underwent test performed in an Instron universal testing machine at a crosshead speed of 1 mm/min. Data were submitted to appropriate statistical tests according to data distribution and assay (p<0.05). Results: Bacterial Adhesion: TM showed a significant reduction on biofilm accumulation in the evaluated periods: 1 day (1.537±0.146); 5 days (2.183±0.138) and 10 days (4.469±0.155) when compared with Control: 1 day (4.954±0.249); 5 days (5.498±0.257) and 10 days (6.306±0.287). Physical Properties: For TBA, SS and DTS no significant difference was found between groups Control and TM. The incorporation of methacrylate triclosan-based monomer in the experimental composite reduce bacterial adhesion of S. mutans and did not affect important polymer properties.


Subject(s)
Triclosan/chemistry , Composite Resins/chemistry , Methacrylates/chemistry , Anti-Bacterial Agents/chemistry , Reference Values , Solubility , Streptococcus mutans/drug effects , Surface Properties , Tensile Strength , Time Factors , Toothbrushing , Triclosan/pharmacology , Bacterial Adhesion/drug effects , Materials Testing , Colony Count, Microbial , Reproducibility of Results , Composite Resins/pharmacology , Hardness Tests , Methacrylates/pharmacology , Anti-Bacterial Agents/pharmacology
13.
Braz. oral res. (Online) ; 33: e083, 2019. tab, graf
Article in English | LILACS | ID: biblio-1019613

ABSTRACT

Abstract This study evaluated the influence of activation modes, on Diametral Tensile Strength (DTS) of dual cured resin cements subjected to a Mechanical Fatigue test (MF). Four dual-cured resin cements (RelyX UNICEM [U], RelyX ARC [A], ENFORCE [E] and Nexus 2 [N]) were activated by three different curing modes as follows: Self-Curing (SC), Dual Cure activation with photoactivation executed directly (DC) and Dual Cure activation with Photoactivation Through Porcelain (DCTP). After 24 hours, half of the sample was subjected to 30.000 fatigue cycles at 1 Hz frequency and 12 N load. Then, all specimens were subjected to DTS test in Instron Universal Testing Machine and data were analyzed by three-way ANOVA and Tukey's Test (5%). The results of DTS test means (MPa) and standard deviation, for each cement factor activated by SC, DC and DCTP was respectively: U (28.12 ± 5.29; 37.44 ± 6.49 and 40.10 ± 4.39), A (49.68 ± 8.42; 55.12 ± 5.16 and 63.43 ± 6.92), E (49.12 ± 3.89; 56.42 ± 8.88 and 56.96 ± 6.45) and N (61.89 ± 11.21; 59.26 ± 9.47 and 62.56 ± 10.93). Turkey's test indicated that DC is related to the highest DTS values; Nexus 2 DTS remained the same independently of activation mode and that the Porcelain disk interposition enhanced DTS only for RelyX ARC the ANOVA statistical test indicated that MF didn't alter the DTS values for all experimental groups. MF results clinical implication is that all cements tested exhibited, in an immediate loading, good cross linked bonds quality.


Subject(s)
Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Ceramics/chemistry , Bisphenol A-Glycidyl Methacrylate/chemistry , Resin Cements/chemistry , Reference Values , Tensile Strength , Materials Testing , Reproducibility of Results , Analysis of Variance , Self-Curing of Dental Resins/methods , Light-Curing of Dental Adhesives/methods
14.
Rev. odontol. UNESP (Online) ; 48: e20190048, 2019. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1043169

ABSTRACT

Abstract Introduction In recent years, there has been an increasing demand for esthetic treatments, especially among orthodontic patients. Objective This study determined the fracture strength of monocrystalline and polycrystalline ceramic brackets of different manufacturers during archwire torque. Material and method Sixty ceramic brackets (Roth, right upper central incisors, 0.022 x 0.028-inch slot) were allocated into two groups (30 specimens per group) according to the type of ceramics: monocrystalline and polycrystalline. Subsequently, the groups were divided into three subgroups (n = 10) according to the manufacturer: Orthometric, Eurodonto and Ortho Technology. Sixty PVC cylinders were filled with chemically activated acrylic resin (CAAR), the brackets were fixed with CAAR onto the cylinder surface and the excess material was used to partially cover the base of the bracket. After 24h, the U-shaped wire base (0.019 x 0.025 inches; 6 mm height and width) was inserted into the bracket slot and fixed thereon with a stainless-steel wire. Vertical folds were made at the ends of the "U" to support the universal test machine chisel. The fracture strength test was performed at a speed of 1.0 mm/min until fracture into a universal test machine (Instron). The data were recorded, transformed into g.mm and submitted to two-way ANOVA followed by Tukey's post-hoc test (SAS Institute Inc., Cary, NC, USA, version 9.3) (α=5%). Result Monocrystalline brackets showed a higher fracture strength than polycrystalline brackets, regardless of the manufacturer (p<0.05). The highest fracture strength values were observed in Ortho Technology and Orthometric brackets, with no significant difference between them (p>0.05). Conclusion Monocrystalline ceramic brackets have a higher fracture strength than polycrystalline brackets, with significant manufacturer-dependent differences.


Resumo Introdução A demanda por tratamentos estéticos tem crescido nos últimos anos, sendo cada vez mais forte a preocupação com a estética por parte dos pacientes que buscam o tratamento ortodôntico. Objetivo Este estudo avaliou a resistência à fratura de bráquetes cerâmicos monocristalinos e policristalinos de diferentes fabricantes quando submetidos ao torque do fio. Material e método Sessenta bráquetes cerâmicos (Roth, incisivos centrais superiores direito, canaleta 0,022 x 0,028 polegadas) foram divididos em 2 grupos (30 espécimes por grupo) de acordo com o tipo da cerâmica: monocristalina e policristalina. Posteriomente estes grupos foram divididos em 3 sub-grupos (n=10) de acordo com o fabricante: Orthometric, Eurodonto e Ortho Technology. Segmentos de fio de aço inoxidável retangular (0,019 x 0,025 polegadas) foram dobrados em forma de "U", sendo que a base do "U" foi inserida na canaleta do bráquete e fixado com fio de amarilho em aço inoxidável (0,008mm). Nas extremidades do "U" foram realizadas dobras verticais para servir de apoio para o cinzel da máquina de ensaio universal Instron. O ensaio de resistência à fratura foi realizado à velocidade de 1,0 mm/min até ocorrer a fratura. Os dados foram registrados, transformados em g.mm e submetidos à ANOVA dois fatores e ao teste de Tukey (SAS Institute Inc., Cary, NC, USA, version 9.3) (α=5%). Resultado Os bráquetes monocristalinos apresentaram maior resistência à fratura em relação aos policristalinos, independente do fabricante (p<0,05). Os maiores valores de resistência à fratura foram obtidos com os bráquetes da Ortho Technology e Orthometric, os quais não diferiram estatisticamente entre si (p>0,05). Conclusão Bráquetes monocristalinos possuem maior resistência à fratura em relação aos policristalinos com diferenças na resistência à fratura entre os diferentes fabricantes.


Subject(s)
Orthodontic Brackets , Torque , Esthetics, Dental , In Vitro Techniques
15.
Braz. dent. j ; 29(3): 268-274, May-June 2018. tab, graf
Article in English | LILACS | ID: biblio-951545

ABSTRACT

Abstract The aim was to evaluate the influence of different dentin preparation mode in the smear layer characteristics (SL), hybrid layer (HL), and microtensile bond strength (µTBS) to dentin with two resin cements. The occlusal dentin of 120 third molars was exposed. The teeth were divided into 4 groups (n=30) according to the dentin preparation mode: 1- fine grain diamond bur; 2- coarse grain diamond bur; 3- multi laminate carbide steel bur; and, 4- ultrasonic CV Dentus diamond bur. Each treated dentin group was divided into 2 sub-groups (n=15) according to the resin cement: (1) RelyX U200 and (2) RelyX ARC. Resin composite blocks were cemented on dentin. After storage at 37o C for 24 h, beams with a cross section area of 1.0 mm2 were obtained, and tested in a universal testing machine at a crosshead speed of 0.5 mm/min. Two additional teeth for each sub-group were prepared to analyze the SL and HL on a scanning electron microscopy. According to Kruskal-Wallis test and Dunn tests, there was no significant difference in µTBS among the rotary instruments within each resin cement group. RelyX ARC obtained higher µTBS values compared to RelyX U200 (p<0.05). RelyX ARC formed evident HL, which was not observed for RelyX U200. The dentin mode preparation did not influence the µTBS of the resin cements. The SL was different for all instruments. The cementing agent is more determinant in the hybrid layer formation and bond strength to dentin than the instruments applied on dentin.


Resumo O objetivo deste estudo foi avaliar a influência de diferentes modos de preparação da dentina nas características da smear layer (SL), da camada híbrida (CH) e na resistência de união à microtração (RUµT) à dentina com dois cimentos resinosos. A dentina oclusal de 120 terceiros molares humanos foi exposta. Os dentes foram divididos em 4 grupos (n=30) de acordo com o modo de preparação da dentina: 1 - ponta diamantada de granulação fina; 2 - ponta diamantada de granulação grossa; 3 - ponta de carboneto de aço multilaminada; 4 - ponta diamantada ultrassônica. Cada grupo foi subdividido em dois subgrupos (n=15) de acordo com o cimento resinoso: (1) RelyX U200 e (2) RelyX ARC. Blocos de resina composta foram cimentados na dentina. Após armazenamento a 37 °C por 24 h, as amostras foram cortadas para obter palitos com área de 1,0 mm2, os quais foram testados em máquina de ensaio universal com velocidade de 0,5 mm/min. Dois dentes adicionais por subgrupo foram preparados para analisar as características da SL e da CH em microscópio eletrônico de varredura. De acordo com o teste de Kruskal-Wallis e o teste de Dunn, não houve diferença significativa na RUµT entre os instrumentos rotatórios para cada cimento resinoso. RelyX ARC obteve maiores valores de RUµT em comparação ao RelyX U200 (p<0,05). RelyX ARC formou uma CH evidente, o que não foi observado para o RelyX U200. O modo de preparação da dentina não influenciou na RUµT dos cimentos resinosos. A SL foi diferente para todos os instrumentos. O agente de cimentação foi mais determinante na formação da camada híbrida e na resistência de união do que os instrumentos utilizados para preparar a dentina.


Subject(s)
Humans , Tensile Strength , Dental Bonding , Dentin-Bonding Agents/chemistry , Resin Cements/chemistry , Dental Cavity Preparation/methods , Dentin/chemistry , Polyethylene Glycols , Polymethacrylic Acids , Microscopy, Electron, Scanning , Smear Layer , Bisphenol A-Glycidyl Methacrylate , Dental Stress Analysis , Molar, Third/chemistry
16.
Braz. dent. j ; 29(1): 76-81, Jan.-Feb. 2018. tab, graf
Article in English | LILACS | ID: biblio-888717

ABSTRACT

Abstract The aim of this study was to evaluate Knoop hardness of different shades of a resin cement light-cured directly or through ceramic discs, measured 15 min or 24 h after light exposure, and at different depths. Specimens of a commercial resin cement (Variolink Veneer) in seven shades, were fabricated in an elastomeric mold, covered with a mylar strip, a 0.7 mm thick ceramic disc (IPS e.max Press) was placed and the cement was light-activated for 20 s using a blue LED (Radii-Cal). The cured resin cement specimens were transversely wet-flattened to their middle portion and microhardness (Knoop) values were recorded at 15 min after light exposure and after deionized water storage at 37 ºC for 24 h. Five indentations were made in the cross-sectional area at 100 and 700 μm depths from the top surface. Ten specimens were made for each test conditions. Data were submitted to ANOVA split-plot design (shade, post-cure time, mode of activation and depth), followed by Tukey post hoc test (α=0.05). Significant differences for shade (p<0.0001), mode of activation (p<0.001), post-cure time (p<0.0001) and depth (p<0.0001) were detected. No significant interactions (p>0.05) were found, except for shade x post-cure time (p<0.0045) and mode of activation x post-cure time (p<0.0003). Resin cement shade has a significant effect on Knoop hardness. Indirect activation through a ceramic material reduced significantly Knoop hardness. Hardness Knoop significantly increased after 24 h in all cements shades compared to values obtained after 15 min. Resin cement depth significantly reduced Knoop hardness.


Resumo O objetivo deste estudo foi avaliar a dureza Knoop de diferentes cores de um cimento resinoso fotoativado diretamente ou através da interposição de um disco de cerâmica, medindo 15 min ou 24 h após exposição à luz, em diferentes profundidades. Amostras do cimento resinoso (Variolink Veneer) em sete cores foram fabricados num molde de elastômero, coberto com tira de poliéster, seguido de um disco cerâmico (IPS e.max Press) com 0.7 mm de espessura e fotoativado por 20 s com o aparelho LED (IPS e.max Press). O cimento resinoso fotoativado foi transversalmente desgastado na porção média e os valores de microdureza Knoop foram obtidos após 15 min após exposição à luz e após armazenagem em água deionizada à 37 °C por 24 h. Cinco penetrações foram feitas na secção transversal à 100 e 700 μm da superfície de topo. Dez amostras foram confeccionadas para cada condição de teste. Os dados foram submetidos à Análise de Variância em esquema de parcelas subdivididas (cor, tempo pós-ativação, modo de ativação e profundidade), seguido pelo teste de Tukey post hoc (α=0,05). Diferença significante para a cor (p<0,0001), modo de ativação (p<0,001), tempo pós-ativação (p<0,0001) e profundidade (p<0,0001) foi detectada. Nenhuma interação significante foi encontrada (p>0,05), exceto para a interação cor x tempo pós-ativação (p<0,0045) e modo de ativação x tempo pós-ativação (p<0,0003). A cor do cimento resinoso teve significante efeito na dureza Knoop. A ativação indireta através do material cerâmico reduziu significativamente a dureza Knoop. A dureza Knoop aumentou significativamente após 24 h em todas as cores do cimento comparados aos valores obtidos após 15 min. A profundidade do cimento resinoso reduziu significativamente os valores de dureza Knoop.


Subject(s)
Ceramics , Color , Hardness , Resin Cements , Curing Lights, Dental , Polymerization
17.
Braz. oral res. (Online) ; 32: e43, 2018. tab, graf
Article in English | LILACS | ID: biblio-889490

ABSTRACT

Abstract To investigate how the hydrofluoric acid (HF) concentrations applied to a lithium disilicate glass-ceramic (EMX) affects the surface morphology and microtensile bond strength (μTBS) of ceramics to dentin, using light-cured resin cements with or without UDMA. Sixty-three EMX square ceramic blocks were etched for 20 seconds using different HF concentrations (1%, 5% and 10%) and luted to dentin using two types of resin cement combinations: BisGMA/TEGDMA and BisGMA/TEGDMA/UDMA (n = 10). Each bonded EMX-dentin block was sectioned to obtain 1 mm2 sticks for μTBS evaluation. Half of the sticks were tested after 24 hours and the other half was assessed after 6 months of water storage. Data were statistically assessed using split-plot three-way ANOVA and multiple comparisons were performed using the Tukey's post hoc test (α = 0.05). One EMX sample from each HF concentration was analyzed using field-emission scanning electron microscope (FE-SEM) to characterize the etching pattern. According to the FE-SEM images, increasing the concentration of HF from 1 to 5 and then to 10% led to increased removal of glassy matrix and greater exposure of lithium disilicate crystals. The 10% HF concentration yielded higher μTBS when compared to 1% for BisGMA/TEGDMA formulation (p < 0.05); whereas HF 1% and 5% showed similar μTBS values when compared to 10% HF for BisGMA/TEGDMA/UDMA resin matrix (p > 0.05) at both storage times. Water aging decreased the μTBS values (p < 0.05), except when 10% HF was associated with BisGMA/TEGDMA resin cement. Resin cement formulation and hydrofluoric acid concentrations can interfere with the immediate and long-term glass-ceramic bond strength to dentin.


Subject(s)
Ceramics/chemistry , Dental Bonding/methods , Resin Cements/chemistry , Dental Porcelain/chemistry , Hydrofluoric Acid/chemistry , Surface Properties , Tensile Strength , Materials Testing , Microscopy, Electron, Scanning , Dental Stress Analysis
18.
Braz. j. oral sci ; 16: e17033, jan.-dez. 2017. ilus
Article in English | LILACS, BBO | ID: biblio-883922

ABSTRACT

Aim: To evaluate, in vitro, the effect of adhesive and bonding materials on the shear bond strength (SBS) of metallic brackets bonded to bovine teeth. Methods: Bovine teeth were embedded with acrylic resin, etched with 35% phosphoric acid for 20 s, rinsed, dried for 20 s and divided into 8 groups (n=20), according to the bonding materials and adhesive: Groups 1 and 5 ­ Transbond XT; Groups 2 and 6 ­ Fill Magic; Groups 3 and 7 ­ Biofix; and, Groups 4 and 8 ­ Orthocem. One layer of adhesive 3 M Unitek (Group 1), and one layer of Single Bond Universal Adhesive (Groups 2, 3 and 4) were applied and light-cured with LED for 10 s. Brackets were bonded to the buccal surface with four bonding materials and light-cured with LED for 40 s. SBS was carried out after 24 h and thermocycling (7,000 cycles - 5°/55 °C). Data were submitted to two way ANOVA and Tukey's post hoc test (α=0.05). The Adhesive Remaining Index (ARI) was evaluated at 8×. Results: The adhesive was effective in increasing the SBS for all bonding materials (p<0.05). Significant difference (p<0.05) on the SBS was observed between bonding materials with or without adhesive. The ARI showed a predominance of scores 0 for all groups. Conclusions: The adhesive improved significantly the SBS of the brackets to teeth. Different SBS values occurred among the bonding materials. ARI index showed predominance of score 0 for all groups (AU)


Subject(s)
Cattle , Adhesives , Orthodontic Brackets , Shear Strength
19.
Braz. dent. j ; 28(4): 474-481, July-Aug. 2017. tab, graf
Article in English | LILACS | ID: biblio-888670

ABSTRACT

Abstract The aim of this study was to evaluate microtensile bond strength (µTBS) of self-etch and etch-and-rinse adhesives systems compared in different dentin regions (central-CD or proximal-PD) in a class II cavity configuration. A class II (mesial-oclusal-distal) cavity configuration was simulated on 20 extracted human third-molars (4 mm wide/3 mm deep). Etch-and-rinse adhesive (Scotchbond Multi Purpose, n=5, SBMP and Optibond FL, n=5, OPFL) and self-etch adhesives (Clearfil SE Bond, n=5, CSE and Optibond XTR, n=5, OPXTR) were applied. Class II restorations were performed by incremental technique and photo-activated (Bluephase/G2). Samples were sectioned to beam shape (1 mm² cross-section), placed on Geraldeli's device for µTBS test (0.5 mm/min cross-head speed). Fracture patterns were analyzed on stereomicroscope and classified as cohesive-resin, adhesive, mixed/resin or mixed/dentin. Samples (n=4) were prepared for scanning electron microscope observation. Data were submitted to one-way ANOVA with Split-Plot arrangement and Tukey's test (α=0.05). There were no statistically significant differences among SBMP, OPFL, CSE and OPXTR on CD (p>0.05). However, on PD for SBMP and OPFL, µTBS values were significantly lower compared to CSE and OPXTR (p<0.05). In all groups, mixed failure pattern was more frequently observed, except for SBMP/CD (adhesive). In class II type cavity configuration, PD location negatively influenced bond strength of etch-and-rinse adhesive systems. Opposite to self-etching adhesives, which presented higher bond strength values compared to etch-and-rinse adhesives in PD.


Resumo O objetivo deste estudo foi avaliar a resistência de união à microtração (µTBS) de sistemas adesivos auto-condicionantes e convencionais comparados por entre diferentes regiões dentinárias (central-DC ou proximal-DP) em um preparo cavitário classe II. Um preparo cavitário classe II (mesio-ocluso-distal) foi simulado em 20 terceiros molares humanos (4 mm largura/3 mm profundidade). Adesivos convencionais (Scotchbond Multi Purpose, n=5, SBMP e Optibond FL, n=5, OPFL) e adesivos auto-condicionantes (Clearfil SE Bond, n=5, CSE e Optibond XTR, n=5, OPXTR foram aplicados. As restaurações classe II foram realizadas usando a técnica incremental e fotoativadas (Bluephase/G2). As amostras foram seccionadas em forma de palito (1 mm2 secção transversal), posicionadas no dispositivo de Geraldeli para o teste µTBS (velocidade transversal de 0,5 mm/min). O padrão de fratura foi analisado em estereoscópio e classificado em coesivo-resina, adesivo, misto/resina, misto/dentina. Amostras (n=4) foram preparadas para observação em microscópio eletrônico de varredura. Os dados foram submetidos a ANOVA um fator e teste de Turkey (α=0,05). Não houve diferença estatística significante entre SBMP, OPFL, CSE, e OPXTR em DC (p>0,05). Entretanto, para SBMP e OPFL em DP, valores µTBS foram significativamente menores comparados com CSE e OPXTR (p<0,05). Em todos os grupos, o padrão de fratura misto foi o mais frequentemente observado, exceto em SBMP/CD (adesivo). Em um preparo classe II, a localização da DP influenciou negativamente a resistência de união de sistemas adesivos convencionais. Oposto aos adesivos auto-condicionantes, que em DP apresentaram valores de resistência de união maiores comparados com adesivos convencionais.


Subject(s)
Humans , Tensile Strength , Dentin-Bonding Agents , Dentin , Materials Testing , Microscopy, Electron, Scanning , Molar
20.
Rev. odontol. UNESP (Online) ; 46(3): 179-183, May-June 2017. tab, ilus
Article in English | LILACS, BBO | ID: biblio-902650

ABSTRACT

Objective: To evaluate in vitro the effect of different treatments of the ceramic surface and thermal cycling on the shear bond strength (SBS) of metallic brackets bonded to feldspathic ceramic. Material and method: Ceramic cylinders were divided into four groups (n=4) according to the treatment of ceramic surface: G1-Clearfil Ceramic Primer silane and Transbond XT (CCPT); G2-etched with 10% hydrofluoric acid (HFA) for 60 s, CCP and Transbond XT (ACCPT); G3-etched with 10% HFA for 60 s, Ambar Adhesive and Transbond XT (AAAT); and, G4 - etched with 10% HFA for 60 s, RelyX Ceramic Primer silane -RCP, adhesive primer Transbond and Transbond XT (ACPPT). Brackets were bonded to the cylinders with Transbond XT and light-activated for 40 s with LED Radii Plus. All specimens were stored in deionized water at 37 °C for 24 h, and two cylinders from each group were subject to 7,000 thermal cycles in a thermal cycler (5 °C/55 °C). After storage and thermal cycling, the SBS test was performed at a crosshead speed of 1 mm/min. Data were subjected to two-way ANOVA and Tukey's post hoc test (α=0.05). Result: The SBS of ACCPT was significantly higher than the other groups (p<0.05). The specimens submitted to thermal cycling showed significantly lower SBS than those without thermal cycling (p<0.05), regardless the ceramic surface treatment. The ARI showed predominance of score 0 for all groups. Conclusion: Acid etching, CCP silane and Transbond XT method obtained the best results for bracket bonding. Thermal cycling reduced SBS for all groups. Score 0 was predominant for ARI in all groups.


Objetivo: Avaliar in vitro o efeito de diferentes tratamentos de superfície da cerâmica e ciclagem térmica na resistência da união ao cisalhamento (RUC) de bráquetes metálicos colados na cerâmica felspática. Material e método: Cilindros cerâmicos foram separados em 4 grupos (n=4) de acordo com os tratamentos da superfície da cerâmica: G1-Clearfil Ceramic Primer silano e Transbond XT (CCPT); G-condicionamento com ácido hidrofluorídrico a 10% (AHF) por 60s, CCP e Transbond XT (ACCPT); G3-condicionamento com AHF a 10% por 60s, Adesivo Ambar e Transbond XT (AAAT); e, G4 condicionamento com AHF a 10% por 60s, RelyX Ceramic Primer silano, primer adesivo Transbond e Transbond XT (ACPAT). Os bráquetes foram fixados nos cilindros com Transbond XT e fotoativado por 40s com LED Radii Plus. Todas as amostras foram armazenadas em água deionizada a 37 °C por 24 h e dois cilindros de cada grupo foram submetidos a 7.000 ciclos térmicos na máquina para ciclagem térmica (5 °C/55 °C). Após armazenagem e ciclagem térmica, a RUC foi realizada à velocidade de 1 mm/min. Na Análise de Variância de 2 fatores e ao teste de Tukey's post hoc test (α=0,05) a RUC do G2 foi significante maior do que dos demais grupos (p<0,05). Resultado: As amostras submetidas à ciclagem térmica apresentaram valores de RUC significantemente menores do que as amostras sem ciclagem térmica (p<0,05), independente do tratamento de superfície da cerâmica. Conclusão: Nas condições desse estudo o melhor resultado para colagem foi obtido com o condicionamento, silano CCP e Transbond XT. A ciclagem térmica reduziu a RUC em todos os grupos.


Subject(s)
Silanes , Ceramics , Analysis of Variance , Orthodontic Brackets , Dental Cements , Shear Strength , In Vitro Techniques , Dental Bonding
SELECTION OF CITATIONS